The shaking table is hydraulically loaded and can simultaneously perform horizontal and vertical two-way vibrations. The maximum load of the shaking table is 1 t, the maximum horizontal displacement is 100 mm, the maximum acceleration is 2.0 g, the maximum velocity is 0.5 m/s, and the operating frequency range observed is 0~50 Hz.
The shaking table model tests of a rock slope reinforced by pile-anchor structures were firstly performed subjected to a suite of real earthquake records with different intensity levels. The seismic responses from the shaking table model tests are then gathered for the optimal analysis to determine the optimal EDP and IM for seismic fragility ...
During the shaking table test, it is indispensable to fully consider the influence of the reinforcement ratio, the model steel bar adopts cold drawn steel wire and galvanized iron wire, and the reinforcement is reinforced according to a similar relationship (Sun, 2013). The reinforcement ratio has an obvious influence on the elastic modulus of ...
In this study, a series of shaking table tests on a pile network composite-reinforced soil high-speed railway subgrade were conducted. Particle image velocimetry was used to analyze the slope motion and sensor data to evaluate the overall dynamic response characteristics of the subgrade. Findings indicate that seismic activity causes subsidence ...
A series of shaking table experimental and numerical research on RERSCS RC solid piers shows the successful seismic response of the Mega-Earthquake-affected high-speed rail (HSR) bridge. The test revealed that the piers maintained outstanding integrity and stability beneath the earthquake action, with a peak ground acceleration (PGA) of 0.96 g ...
The density, particle size and shape of the medium ore particles have a great influence on the sorting index when the shaking table is used for ore feeding. When the density difference between heavy minerals and light minerals is greater than 1.5, it can be successfully sorted on a shaking table. Spherical-like ore particles and coarse ...
The seismic response characteristics of a subway station structure were studied at Xi'an University of Architecture and Technology, using a shaking table to investigate the dynamic response of such structures under seismic excitations. The shaking table had dimensions of 4.1 m × 4.1 m and a maximum load capacity of 20 tons under full load.
Brazil is the tenth largest iron exporter, maintaining a commercial relationship with more than 110 other countries. The three largest importers of Brazilian ores are the USA, Turkey, and Germany. Brazilian iron ore exportation in 2017 represented 3% of all ore exported worldwide. In 2018, Brazil has exported 6.9 million tons of iron .
TABLE OF CONTENTS PAGE 1 INTRODUCTION 1-1 2 SYSTEM CHARACTERISTICS 2-1 2.1 Shaking Table Configuration 2-1 2.2 Performance Limitation 2-3 2.3 Three Variable Control System 2-5 2.4 Off-line Compensation Technique 2-5 2.5 Data Acquisition System 2.7 3 DYNAMIC PERFORMANCE 3-1 3.1 Simulation For Real Earthquake Record Without System …
PETROBRAS-Petroleo Brasileiro S A Brazil has Released a tender for Acquisition Of Shaking Table For Laboratory With Associated Services in laboratory equipment and services . The tender was released on Nov 26, 2024. Country - Brazil. Summary - Acquisition Of Shaking Table For Laboratory With Associated Services. Deadline - login to view
6-S Shaking Tables not only widely applied on separating Gold, Tungsten, Tin, Manganese, Iron, Titanium, Zircon, Tantalum, Barium, Chrome, Lead, Zinc, Mercury, Copper, Aluminum,and other rare metals and the noble metal ore, also applied on sorting coal.When dealing with the metal ore, the shaker effective recycling granularity scope is 2-0.037 millimeters.
Shaking Table Testing of Buildings (a) 10-story RC frame-wall buildings (b) 3-story reinforced masonry buildings (c) 2-story unreinforced masonry buildings (d) 6-story precast concrete buildings (e) single-story URM out-of-plane walls (f) anchorage of brick veneer (g) shaking table tests of buildings done by others ...
This paper details how to construct a small-scale shaking table attached to a magnetorheological (MR) damper. ... Av. Alberto Carazzai 1640, Cornelio Procópio 86300-000, Brazil. 2 Centro de Ciências Exatas e Tecnologia, Faculdade de Engenharia Mecânica, Universidade Federal de Uberlândia, UFU, Av. João Naves de Ávila 2121, Uberlândia ...
The shaking table test was completed in the earthquake simulation shaking table laboratory of the South China University of Technology, as shown in Fig. 6. The shaking table size is 4 m × 4 m, the maximum load capacity is 30 tons, and the maximum input acceleration in the horizontal and vertical directions are 1.0 g and 2.0 g, respectively.
A shaking table model test was carried out to study the failure mechanism of an anti-dip rock slope with complex structural planes. The effect of the input seismic wave frequency, types and structural plane on the slope's dynamic response were considered. The test results show that the input seismic wave frequency is closer to the slope's natural frequency, the …
Shaking table separation is the gravity concentration process in which the combined action of the asymmetric reciprocating motion of the table and the water flow on the thin inclined layer separates the mineral particles according to their densities on a wide inclined table. Shaking table separation is suitable for separation of fine particle ...
2129 1 National Laboratory For Civil Engineering, Av. Brasil 101 - 1700-066 Lisboa Portugal, E-Mail:[email protected] 2 National Laboratory For Civil Engineering, Av. Brasil 101 - 1700-066 Lisboa Portugal, E-Mail:[email protected] SHAKING TABLE TESTING OF CIVIL ENGINEERING STRUCTURES - THE LNEC 3D SIMULATOR EXPERIENCE Rogerio BAIRRAO1 And Carlos …